Brand
Petronas
Type
Hydraulic oils
Viscosity
ISO VG 46
Manufacturer code
77558

Petronas Hydraulic ZF 46

Premium zinc-free hydraulic oil for water-exposed systems

Specifications

Viscosity
ISO VG 46
Manufacturer code
77558
Availability
On order

Manufacturer's description

PETRONAS Hydraulic ZF 46 belongs to the premium performance, ashless PETRONAS Hydraulic ZF Series, specially created for a wide range of mobile and industrial hydraulic equipment operating under normal to heavy-duty conditions and in the presence of water that could otherwise cause filter blocking. It is recommended for systems with smaller reservoirs and coolers generating high thermal stress, systems sensitive to sludge and varnish formation with tight-tolerance pumps and servo valves, and systems demanding long-life lubricants. Formulated with high quality selected base oils and advanced zinc-free anti-wear, antioxidant, anti-rust and anti-foam additives, it delivers excellent anti-wear protection under demanding operating conditions and an oxidation life up to 5 times longer than standard fluids, with a TOST life exceeding 10,000 hours against a minimum requirement of 1,000 hours. Grade 46 has a kinematic viscosity of 46 cSt at 40°C and 6.8 cSt at 100°C, a viscosity index of 102, a flash point of 220°C and a pour point of -33°C. PETRONAS Hydraulic ZF Series meets or exceeds ASTM D6158 HM, DIN 51524 Part II HLP, ISO 11158 HM, Eaton E-FDGN-TB002-E, Fives Cincinnati P-68/P-69/P-70, Parker Denison HF-0/HF-1/HF-2, GB 11118.1 L-HM and SS 155434:2015 Type M.

Standards & approvals

  • GB 11118.1 L-HM (high pressure)

    GB 11118.1 L-HM — hydraulic oil (China)

    The Chinese national standard for hydraulic fluids; class L-HM is the antiwear oil, with a high-pressure variant.

  • Eaton E-FDGN-TB002-E

    Eaton E-FDGN-TB002-E — hydraulic fluids

    The Eaton technical bulletin listing the requirements for hydraulic fluids in Eaton and Vickers equipment, including the vane pump wear test.

  • ISO 11158 HM (FDIS 2008)

    Hydraulic oil, type H HM (FDIS 2008) — ISO 11158

    The international standard for mineral hydraulic fluids; class HM is the antiwear oil, the ISO counterpart of DIN 51524-2 HLP.

  • Fives Cincinnati P-68

    Fives Cincinnati P-68 — ISO VG 32 hydraulic oil

    An approval number from the Fives Cincinnati list of fluids for use in its own machine tools. Approved hydraulic fluids must pass its own wear, filterability and water separation tests, beyond the DIN 51524-2 level.

  • Fives Cincinnati P-69

    Fives Cincinnati P-69 — ISO VG 68 hydraulic oil

    An approval number from the Fives Cincinnati list of fluids for use in its own machine tools. Approved hydraulic fluids must pass its own wear, filterability and water separation tests, beyond the DIN 51524-2 level.

  • Parker Denison HF-0

    Parker Denison HF-0 — hydraulic fluid, most severe level

    The most severe level of the Denison hydraulic fluid specification: the oil must pass the wear test on both a vane pump and a piston pump, dry and in the presence of water. HF-0 subsumes HF-1 and HF-2.

  • Parker Denison HF0/HF1/HF2

    Parker Denison HF-0, HF-1 and HF-2

    The three Denison hydraulic fluid levels quoted together. An oil covering all three passes the vane pump and piston pump tests alike, including in the presence of water.

Also listed

  • ASTM D6158 HM (2016)
  • DIN 51524 Part II HLP (2017) (2011)
  • GB 11118.1 L-HM General (2011)
  • SS 155434:2015 Type M

Approved for

  • ZF
  • Denison
  • Eaton
  • ISO
  • DIN
  • Parker

Typical characteristics

PropertyTypical valueLimitMethod
Specific gravity @15°C0,877ASTM D 4052
Kinematic viscosity at 40°C, cSt46±10%ASTM D 445
Kinematic viscosity at 100°C, cSt6,8ASTM D 445
Viscosity index102ASTM D 2270
Flash point, °C220ReportASTM D 92
Pour point, °C-33ASTM D 97
TAN, mgKOH/g0,08ASTM D 664
FZG, failure load stage12Min. 10ISO 14635-1
Water separability, 40/37/3 - mins15ASTM D 1401
Copper strip corrosion1bMax. 2ASTM D 130
TOST life, hours>10000Min. 1000ASTM D 943
Foam Sequence I, mL0/00/0Max. 150/0
Foam Sequence II, mL0/0Max. 75/0ASTM D 892
Foam Sequence III, mL0/00/0Max. 150/0

Packaging

  • 20 L

Complete documentation

We email you the sheets listed below in a single archive. No account, no order required.

  • SDSEN
  • SDSRO
  • TDSEN
  • TDSRO

Where should the files go?

We send the archive to the address below. It is the only field we need — the rest only help us reach you if a sheet is missing.

What you get

    Str. Soporului, nr. 12, Cluj-NapocaContactAbout us
    RO